Eagle 2D Pan

The Eagle 2D Pan offers all panoramic profile exams, such as:
standard panoramic, maxillary sinus, low dosage, bitewing, ATM, enhanced orthogonality, panoramic for children and enhanced bitewing orthogonality.

The Eagle 2D Pan enables upgrade to the Pan/Ceph version with two sensors, to the Pan/3D VBeam version and to the Pan/Ceph/3D VBeam version with FOV up to 23x16.
The Eagle line offers high image quality, easy handling, easiness in positioning the patient and gathers state-of-the-art world technology for all functions. The high frequency X-ray generator reduces unnecessary patient exposure.

The micro-processed high speed system and accurate mechanics allow for perfect execution and repeatability in 2D and 3D images.

Eagle Technology

Upgrade

Eagle is built on an intelligent platform that allows upgrade between versions! You can buy a Pan system and upgrade later to Ceph and 3D.

Easily Patient Positioning

The adjustable height of between 1,20m and 2m, for the frontal positioning of the patient in relation to the operator, tooth clamp with swivel brake, chin support, temple support and three laser beams, guaratee precise positioning of the patient.

Automatic Processing

Regardless of the chosen profile, the images are automatically processed and displayed within the sharpen, brightness and contrast parameters previously determined, giving agility to the workflow and standardization of the exams.

DICOM SERVER

The Eagle DICOM Send software tool permits the instant transmission of images generated by Eagle to storage and sharing systems in physically separate locations; an extremely useful resource for clinical networks that can decentralize image acquisition and centralize reports.

Constant Vertical Magnification

Robotic movement system with microstep drive provides smooth movements without vibrations, developed especially for ultra high images in dentistry. Eagle’s leading-edge system introduces three axes, with two orthogonal directions and one rotation, allowing for greater flexibility in the setting of radiographic profiles, optimization of the slice thickness plane, constant vertical magnification and consequently better images.

Eagle Smart Contrast

Eagle Smart Contrast® algorithm is an innovative tool that operates in all image regions , individually treating and enhancing the contrast of each area. The result is a homogeneous image without noise, allowing the visualization of details and consequently a better diagnosis.

Get the images on iPad

Eagle software allows instantaneous communications through wireless connections from other computers, iPad, and tablets or notebooks. You save time, share images across the network, and impress customers with the technology of your clinic.

Supply Voltage 110/127/220 ou 240V
Power Consumption 1,25 KVA
Operating Frequency 50 ou 60 kHz
Generator Type High Frequency
Focal point 0,5mm
Voltage tube 60-85kV
Tube current 6,3-8mA
Image detector CCD
Pixel size 108 µm (Pan and Ceph)
Display LCD
Panoramic Profile Yes
Cephalometric Profile Yes
Tomography (3D) Profile Upgrade
Sensor quantity 1 sensor or 2 sensores
Base Optional
Acessible to wheelchair user Yes


PAN
Exposure (time/current):
PAN - Standard 14s - 8mA
Improved Ortogonally 14s - 8mA
PAN - low dosage 13s - 6,3mA
PAN - children 11,5s - 6,3 mA
Bitewing 7,6s - 8mA
Improved Ortogonally Bitewing 7,6s - 8mA
Maxillary Sinus 8s - 8mA
ATM 10s - 8mA
Average expasion 1:1,22


CEPH
Expoure (time/current):
Ceph - Analogic 0,1 a 3s - 8mA
Ceph - Full digital 10 ou 16s - 8mA
Ceph - Full Digital (low dosage) 6,6 ou 11s - 8mA
Average expasion 1:1,11


COMPUTER SPECIFICATIONS
Operating System Windows 7 Professional - 64Bits
Windows 8 Professional - 64Bits
Windows 8.1 Professional - 64Bits
Windows 10 Professional - 64Bits
CPU Intel Core i5 3.6 GHz or higher
RAM 8GB DDR2 SDRAM
HDD 1TB or higher
PCI 2x PCI Express (PCIe) slot
NIC Gigabit Ethernet dedicated
Video -
USB Connector 2x USB 2.0
Monitor 1920 x 1080 - Full HD
Power Suply 400W RMS with supplementary power connectors PCI Express compatible with video board


MINIMUM DIMENSIONS OF THE ROOM
Width 1,8m
Length 1,9m (Without cephalometric arm)
2,5m (with cephalometric arm)
Height 2,5m
2D Radiographic exams - Pan Profiles
Standard pan
This exposure has constant vertical magnification in the region of the dental arch, provides great width to the cutting plane and prioritises uniformity of the exposure throughout the image.

T.M.J
This double exposure shows the region of the dental condyles with the mouth open and closed in the same image.
Maillary sinus
This exposure focuses on the maxillary sinus region.
Improved ortogonally*
This exposure contains the standard pan profile with improved orthogonality for the beams in relation to angles thus providing for reduced reassembly of teeth on the exposure.
Low dosage*
This exposure corresponds to the standard panprofile and is perfomed ina fast exporure and using a lower anode current (mA). The image quality is still suitable for diagnosis although the dosage is less tha that for standard pan exposure with great image quality.
Children pan
This exposure features a reduced profile, 15% less tha for the standard pan.
Bitewing
This exposure has an image profile type for the bitewing area of the pre-molars and molars, including part of the maxilla, mandible and mandibular ramus.
Improved ortogonally bitewing*
This exposure contains the bitewing profile with improved orthogonality for the beams in relation to angles thus providing for less reassembly of teeth on the exposure.
2D Radiographic exams - Ceph Profiles
Digital ceph profile
With this profile it is possible to obtain the following digital images:
PA; Posterior-Anterior
AP; Anterior-Posterior
45 Degrees
Lateral
Carpal
PA de Water´s View
Axial Basal - Hirtz View.

Low dosage digital ceph profile*
With this profile it is possible to obtain a lateral display with a reduced exposure area and thus a reduced dosage for the patient.
*Available only on the digital version.

Owner´s Manual
In order to ensure correct use, we recommend reading the owner's manual.